Dynos & dynamometersFind the right type of dynamometer for your specific application!

Call for free technical assistance on building your own system.

Pick the best style dynamometer for your application! Each type of configuration has its own strengths and weaknesses. The chart below attempts to point out some of the more significant differences.

Custom hybrid configurations using a combination of both an AC Motor/Generator and Eddy-Current (or water brake) absorber can provide the unique characteristics of each - in a single installation. This means it is practical to have instantaneous control, stability, motoring capability, and high power absorption that would be otherwise unaffordable (or impossible) to duplicate. Control of the pair is done using DYNO-MAX 2000 “Pro” software. In very high Hp installations it is possible to reduce, significantly, both the dynamometer’s cost and inertia via this method.

 

Feature Water Brake Absorbers Inertia
Rollers
Inertia+
Parasitic
Fan/Pump
Eddy Current
Absorbers
Friction Brakes Hydraulic Pumps

AC Motor- Generators

DC Motor- Generators
High Hp (steady state) capacity? Excelente n/a* Fair
(depends on fan size)
Bueno Pobre
(cooling required
Fair
(cooler required
Bueno Fair
High RPM capability? Excelente n/a Fair
(fan limited)
Fair Bueno Pobre Fair Pobre
Low RPM torque
(steady state) capacity?
Fair n/a* Pobre Muy Bueno Excelente Excelente Excelente Excelente
Stall torque
(0 RPM range)
test capability
?
Pobre Fair
(startup only)
Fair
(startup only)
Pobre Bueno Bueno Excelente
(with encoder)
Excelente
(with encoder)
Stability of
RPM load control?
Bueno n/a* n/a*
(exponential
fixed curve)
Muy Bueno Pobre Fair Excelente Muy Bueno
Typical response time to 90% load change? Bueno
(less than 0.5 seconds)
n/a* n/a*
(exponential
fixed curve)
Muy Bueno
(less than 0.05 seconds)
Pobre
(less than 1.0 seconds)
Fair
(less than 0.75 seconds)
Excelente
(less than 0.005 seconds)
Muy Bueno
(less than 0.01 seconds)
Testing simulation under computer control? Bueno n/a* n/a*
(exponential
fixed curve)
Excelente Fair Not typically available Excelente Muy Bueno
Motoring capability? requires separate motor requires separate motor requires separate motor requires separate motor requires separate motor requires separate motor Excelente Excelente
Suitability to long duration testing? Excelente n/a* Excelente Excelente(water cooled)
Fair (air)
Fair
(water cooled)
Bueno
(with cooler)
Excelente Bueno
Ease of engine starting? requires separate starter requires separate starter requires separate starter requires separate starter requires separate starter requires separate starter Excelente Excelente
Hp capacity
vs. weight?
Excelente Pobre Pobre Fair Fair Fair Pobre Pobre
Hp capacity
vs. size?
Excelente Excelente Excelente Fair Bueno Bueno Fair Pobre
Portability of
absorption unit
Excelente Determined by weight Determined by weight Fair Fair Bueno Pobre Pobre
RPM, Torque, &  Hp Accuracy? Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition
Data Repeatability? Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition Determined by Data Acquisition
Resistance to hysteresis (breakaway friction) Bueno Excelente Excelente Muy Bueno Bueno Pobre Muy Bueno Bueno
Immunity to un-trunioned parasitic drag losses Excelente
(if mounted directly)
Pobre Pobre Bueno Bueno Fair Excelente
(with in-line transducer)
Excelente
(with in-line transducer)
Affordability per Hp
(steady state) capacity?
Excelente n/a* Fair Bueno Fair Fair Pobre Pobre
Installation affordability? Excelente
(if water is available)
Fair
(if pit or lift required)
Fair
(if pit or lift required)
Muy Bueno
(115v AC required)
Bueno
(but cooler required)
Bueno
(but cooler required)
Bueno
(electrician required)
Bueno
(electrician required)
Affordability of  maintenance? Excelente Excelente Excelente Excelente Fair Bueno Excelente Bueno

*n/a - no se aplica, la inercia sólo "dynos" no se puede medir directamente el par o mantener un estado de equilibrio de carga (sin ser
equipadas también con algún tipo de amortiguador y célula de carga o una fuente de los rozamientos parásitos (por ejemplo, un gran
ventilador o con una bomba conocida curva de pérdida).    © 10/4/2008


DYNO-mite dinamómetro

Para recibir asistencia técnica para su DYNO-mite, comuníquese por teléfono o por correo electrónico: sales@land-and-sea.com
© 13 Mar 2009 Land & Sea, Inc. 25 Henniker Street; Concord, NH 03301-8528 USA +1-603-226-3966